ECOTRONIC Plus
© Ferroli 08164 ECOTRONIC Plus.monen.indd
1. Select basic solar system
(Solar/Options/System)
2. Select hydraulic variant (beginning with system 2)
(Solar/Options/loading)
3. Adjust date and time
(arrangement/adj. values/time)
4. Activate internal heating circuit module if needed
(arrangement/heat. circuits/Options/heat. circ.)
5. Adjust parameters for internal heating circuit module
(Arrangement/heat. circuits/heat. circ./...)
6. Activate external heating circuit module if needed
(arrangement/heat. circuits/Options/HC module)
7. Adjust parameters for external heating circuit module
(arrangement/heat. circuits/Hc Module/...)
8. Activate desired functions with relay allocation (if needed)
Bypass
(Solar/Options/Bypass)
External heat exchanger
(Solar/Options/Ext. heat. ex)
Cooling function
(Solar/Options/cool. func.)
Parallel relay
(Solar/Options/Par.Relay)
After-heating suppression
(Solar/Options /ah suppress.)
HSE
(arrangement/Options/hse)
Store loading
(arrangement/Options /store load.)
Error message
(Expert/message rel.)
3.4 Adjusting the controller step-by-step
Before adjusting the controller, select the language (Expert/language/...).
Points 1. – 3. have to be adjusted for all systems, points 4. – 18. aree adjusted optional to suit the system requirements,
points 19. and 20. should be adjusted before the system is handed over to the operator.
9. Activate further functions without relay allocation (if
needed):
Tube collector function
(Solar/Options/tube col.)
Collector cooling function
(Solar/Options/col. cooling)
Recooling function
(Solar/Options/Recooling)
Frost protection
(Solar/Options/frost. prot.)
Target temperature
(Solar/Options/target tem.)
CS-Bypass
(Solar/Options/CS-Bypass)
10. Adjust special parameters of the selected options
(Solar/adj. values/...),
(Solar/Expert/...) and
(Arrangement/adj. values/...)
11. Activate functions of function blocks (if needed)
(arrangement/Options/...)
12. Adjust switching conditions for the activated functions
(Arrangement/adj. values/...)
13. Activates heat measurement function(s) (if needed)
(WMZ/Options/...)
14. Adjust special parameters
(WMZ/WMZ 1 (2)/Expert/...)
15. Deactivate warning message (if needed)
(Expert/...)
16. Carry out sensor offset (if needed)
(Expert/Sensors/...)
17. Increase minimum speeds (if needed)
(Expert/Relay/...)
18.Setup and adjust chimney sweeper function (if needed)
(Expert/chimney sweeper/...)
19. Carry out relay test
(manual operation/...)
20. Save adjustments
(user code/000)