A. Technical appendix
A-4
Festo P.BE-CTEU-EC-OP+MAINT-EN en 1208NH
General
Materials
– Housing
– Housing cover, cover for DIL switches
– Threaded sleeve M12
– Threaded bush M3
– Seals
–Screws
RoHS-compliant
PA, reinforced
PC
Brass, galvanically nickel-plated
Brass
Nitrile rubber
Galvanised steel
Explanation on vibration and shock – severity level
Severity level 1
(SL1, in accordance with EN 60068,
part 2 – 29)
Vibration:
0.15 mm path at 10 … 58 Hz;
2 g ac c eleration at 58 ... 150 Hz
Shock:
±15 g at 11 ms duration;
5 shocks per direction
Continuous shock:
±15gat6msduration;
1000 shocks per direction
Severity level 2
(SG2, in ac cordance with EN 60068,
part 2 – 27)
Vibration:
0.35 mm path at 10 … 60 Hz;
5 g ac c eleration at 60 ... 150 Hz
Shock:
±30 g at 11 ms duration;
5 shocks per direction
Continuous shock:
n. a.