5. Maintenance and conversion
5−23
Festo P.BE−MPA−EN en 0910d
Dismounting Proceed as follows:
1. Loosen all valve plates and blanking plates on the
sub−base from which you wish to remove the interlinking
board (see section 5.3.3).
2. Remove the electronics module from the sub−base
(seesection 5.3.5).
3. Loosen the sub−base from the neighbouring components
(see section 5.3.6).
4. If you wish to remove the last interlinking board in front of
the right−hand MPA end plate, you must remove the end
piece type MPA from this interlinking board.
1 End piece
Type MPA
1
Fig.5/9: Removing the end piece from the last interlinking board
5. Loosen the corresponding interlinking board from above
by unlocking the locking clips (e.g. with a small
screwdriver). Then pull the interlinking board to the right
out of the sub−base.