EasyManua.ls Logo

Festo MPA Series - Page 180

Festo MPA Series
218 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A. Technical appendix
A−6
Festo P.BE−MPA−EN en 0910d
General information
Vibration and shock
1)
2)
4)
Vibration
Shock
Continuous shock
tested as per DIN/IEC68 / EN60068 part 2 − 6,
With horizontal H−rail fitting: Severity class 1
With wall mounting:
2)
3)
tested as per DIN/IEC68 / EN60068 part 2 − 27,
With horizontal H−rail fitting: Severity class 1
With wall mounting:
2)
3)
tested as per DIN/IEC68 / EN60068 parts 2 − 29,
With wall and H−rail mounting: Severity class 1
1)
Specifications on vibration and shock of the CPX terminal can be found in the description of
the CPX system.
2)
MPA−S valve terminal with CPX terminal:
up to a length of 280 mm between the pneumatic interface and the right−hand end plate,
without additional fastening: Severity class 2
as from a length of 280 mm between the pneumatic interface and the right−hand end plate, with
additional fastening on the pneumatic supply plates: Severity class 2
3)
MPA−S valve terminal with CPI, with ASI or with multi−pin plug connection:
up to a length of 280 mm of the valve terminal without additional fastening Severity class 2
as from a length of 280 mm of the valve terminal with at least one additional fastening in the
centre of the valve terminal to the pneumatic supply plate: Severity class 2
4)
See following table for explanations of the severity levels.
Tab.A/2: Vibration and shock
Seve
rity
level
Vibration Shock Continuous shock
1 0.15 mm travel at 10−58 Hz;
2 g acceleration at 58−150 Hz
±15 g for 11 ms duration,
5 shocks per direction
±15 g for 6ms duration;
1000 shocks per direction
2 0,35 mm travel at 10−60 Hz;
5 g acceleration at 60−150 Hz
±30 g for 11 ms duration,
5 shocks per direction
−−−−−
Tab.A/3: Values for vibration and shock as per DIN/IEC68

Table of Contents