1. Summary of components
1-18
Festo P.BE-SPC11 -DGP-EN en 0012NH
Using the complete cylinder stroke
If using complete the cushioning length, please observe the
following:
If the DGP(L)-... is used, the potentiometer must be longer
thanthecylinderstrokeused.Theremustbeanelectric
reserve. The following maximum stroke lengths can be
used:
Measuring system length
[mm]
Max. usable stroke length
[mm]
225 215
300 290
360 350
450 440
500 490
600 590
750 735
1000 985
1250 1230
1500 1475
1750 1720
2000 1965
S Mount the measuring system and the drive symmetrically,
so that the centre of the measuring sy s tem s troke
matches the centre of the complete drive stroke (see also
System manual type P.BE-SPC11-SYS-...).
The resulting positioning times depend on the actual
stroke length used.