2.4.5 DGP(I)(L)-63-... in vertical operation
DGP(I)(L)-63-225 to ...-63-360 in vertical operation
DGP(I)(L)- 63-225 DGP(I)(L)-63-300 DGP(I)(L)-63-360
MPYE-5-1/8- LF- 010B MPYE- 5-1/8- HF-010B MPYE- 5-1/4- 010B
Mass [kg]
Amplification stage
Cushioning stage
System parameter
Time upwards [s]
Time downwards [s]
Amplification stage
Cushioning stage
System parameter
Time upwards [s]
Time downwards [s]
Amplification stage
Cushioning stage
System parameter
Time upwards [s]
Time downwards [s]
12 18 14 28
0.99 0.93
16 15 36
1.01 0.92
14 20 25
0.78 0.74
24 20 17 28
1.03 1.12
19 22 36
1.06 0.93
16 21 25
0.78 0.70
36 21 23 28
1.12 1.13
20 24 36
1.17 0.93
18 22 25
0.84 0.70
48 22 23 28
1.18 1.20
21 25 36
1.18 0.93
19 23 25
0.87 0.65
60 23 23 28
1.21 1.08
22 24 36
1.18 0.88
20 25 25
0.86 0.72