2. Parameters of the SPC11 for the DGP(I)(L)-...
2-8
Festo P.BE-SPC11 -DGP-EN en 0012NH
2.3 Parameters for the DGP( I)( L)-.. in horizontal operation
2.3.1 DGP(I)(L)-25-... in horizontal operation
DGP(I)(L)-25-225 to ...-25-360 in horizontal operation
DGP(I)(L)- 25-225 DGP(I)(L)-25-300 DGP(I)(L)-25-360
MPYE-5-1/8- LF- 010B MPYE- 5-1/8- LF-010B MPYE- 5-1/8- H F-010B
Mass [kg]
Amplification stage
Cushioning stage
System parameter
Time [s]
Amplification stage
Cushioning stage
System parameter
Time [s]
Amplification stage
Cushioning stage
System parameter
Time [s]
2 8 15 01 0.47 12 16 02 0.52 11 18 10 0.43
4 11 18 01 0.49 14 19 02 0.54 12 21 10 0.49
6 12 20 01 0.50 16 21 02 0.53 13 22 10 0.51
8 14 22 01 0.49 17 23 02 0.58 14 24 10 0.53
10 14 24 01 0.59 18 24 02 0.61 15 25 10 0.58
12 15 25 01 0.57 18 26 02 0.65 16 26 10 0.57
14 16 25 01 0.59 19 27 02 0.66 17 26 10 0.61
16 16 27 01 0.69 20 27 02 0.71 17 27 10 0.61
18 17 27 01 0.61 20 30 02 0.77 18 28 10 0.61
20 17 28 01 0.67 20 29 02 0.75 18 28 10 0.64
22 18 28 01 0.64 21 29 02 0.69 19 29 10 0.63
24 18 29 01 0.67 21 30 02 0.80 19 29 10 0.65
26 18 29 01 0.68 22 29 02 0.71 19 30 10 0.70
28 19 30 01 0.73 22 31 02 0.76 20 30 10 0.72
30 19 29 01 0.69 22 32 02 0.80 20 31 10 0.72