Chapter 4: Diagnostics and Troubleshooting
4-7
Error Number 14
The x-ray counts detected by the scintillation tube decreased
rapidly to a value that is 75 percent below the average count for the
last eight containers. Report this error to your Service Department.
Error Number 15
The missing cap sensor input state logic level remains high. This
occurs when two or more consecutive signals are received from the
trigger beam, which indicates containers are passing through the
unit, and no signals are received from the missing cap sensor.
Report this error to your Service Department.
Error Number 16
The trigger beam is not sensing containers. The x-ray count pattern
indicates containers are passing through the X-ray beam, however
no trigger signal is received. Report this error to your Service
Department.
Error Numbers 19 and 20
These errors pertain to label inspection. Report these errors to your
Service Department.
Error Number 22
This error occurs when an encoder pulse is missed. The encoder
may be failing. Report this error to your Service Department.
Error Number 23
This error occurs when an extra encoder pulse is detected. This
error can occur when the conveyor stops or starts suddenly. If this
error persists, report this error to your Service Department.
Error Number 24
Report this error to your Service Department.
Error Number 25
Report this error to your Service Department.