Chapter 4: Diagnostics and Troubleshooting
4-9
Error Number 49
The User Defaults loaded for one or more settings are out of range.
Check all settings to be sure they are correct. This is a high priority
error condition and will cause the Warning Beacon to flash if
Beacon Status is set to HIGH PRIORITY ONLY. Report this error to
your Service Department.
Error Number 50
The System defaults loaded for one or more settings are out of
range. A complete software setup must be performed. This is a
high priority error condition and will cause the Warning Beacon to
flash if Beacon Status is set to HIGH PRIORITY ONLY. Report this
error to your Service Department.
Error Number 51
A container passed without any encoder pulses. This can be
caused by:
• blocking the trigger with the line stopped
• encoder failure
• trigger reflections
• line jams
This error condition is low priority and will not cause the Warning
Beacon to flash during HIGH PRIORITY ONLY operation. If this
error persists, report this error to your Service Department.
Error Number 52
A container passed the trigger in less than 10 ms. This can be
caused by trigger reflections or line jams. If this error persists,
report this error to your Service Department.
Error Number 53
The Reject Watchdog detected a queue error. If this error occurs
repeatedly, call IDC technical support.
Error Number 54
This error displays the Reject Queue Count. If this error occurs
repeatedly, call IDC technical support.