15
STARTING PROCEDURE
See HYDROSEEDER
®
SAFETY SUMMARY SECTION before operating
the machine. Failure to comply could result in death or serious injury.
Failure to comply could also result in product or property damage.
Before starting, open the recirculation valve, close discharge valve and recirculation valve (if
applicable), disengage clutch, and place the agitator control in the NEUTRAL position.
1. Set throttle about 1/4 open.
2. Turn the key clockwise until the starter engages, and the engine starts.
3. Allow engine to warm up for 3 to 5 minutes.
NOTE: This engine has a safety system that will shut the engine off if the engine
oil pressure drops below 7 psi (48 kPa) or if the water temperature reaches
230˚F (110˚C).
POWERVIEW
The PowerView is a multifunctional tool that enables the operator to view many different engine
parameters and service codes. A graphical back-lit LCD screen can display either a single parameter
or a quadrant display showing four parameters simultaneously. Diagnostic capabilities include fault
codes with text translation for the most common fault conditions.
The following relative engine parameters can be displayed in either English or Metric units, as well
as in Spanish, French, or German:
• Engine Rpm
• Engine Hours
• System Voltage
• % Engine Load at Current RPM
• Coolant Temperature
• Oil Pressure
• Throttle Position
• Active Service Codes
Figure 7 – Faceplate Features
AMBER
WARNING LED
RED SHUTDOWN
DERATE LED
DISPLAY
BEZEL
MENU KEY ENTER KEY
LEFT
ARROW KEY
(Scroll Up)
RIGHT
ARROW KEY
(Scroll Down)