31
APPLICATION OF SLURRY (CONTINUED)
C. HOSE WORK WITH REMOTE TRANSMITTER
1. Begin with the engine around 1/4 throttle (1,400 rpm).
2. Close recirculation valve. If using an extension hose connected to the discharge boom, open
discharge valve. If using the hose reel, close discharge valve and open pump take off valve to
the hose reel.
3. Switch Remote On/Off switch on the control panel to the ON position.
4. When the operator is in position, engage the pump using the remote transmitter and increase
throttle to the desired output.
NOTE: To quickly shut off engine at any time, press the red Emergency Stop button
on the transmitter. To restart engine, the key switch on the control panel must
be returned to the OFF position and then restarted.
5. When finished spraying, turn pump off and decrease engine throttle to idle.
When using the remote transmitter option, the secondary operator(s)
must be aware that the machine can be activated remotely at any time
after the Remote On/Off switch on the control panel is switched ON. If any maintenance or
troubleshooting needs to be performed while the engine is running, the Remote On/Off switch
must be in the off position. Failure to comply could result in minor or moderate personal
injury. Failure to comply could also result in product or property damage.
RELOADING PROCEDURE
1. Start at step 2 in LOADING.
2. After last load of the day, refer to CLEANING AND MAINTENANCE section.
3. If the unit is equipped with an Air Flush System, refer to the Air Flush System Parts and
Operator's Manual.