1. Feed water hardness (Display Code H)
The feed water hardness setting displays only if the system is set to operate as a Meter Immediate or Meter
Delayed system type.
— Press the Set Up and Set Down buttons to set the amount of feed water hardness (grains/gallon or
degrees). The system automatically calculates treated water capacity based on the feed water hardness
and the system capacity preset in the Master Programming mode.
Example: Range: 4 – 199 US and Metric
— To program 9 grains / gallon (US) or 9 degrees (Metric) [H – 9]
— Press the Set Up and Set Down buttons to adjust this value.
— Press the Extra Cycle button once to Exit Setup Programming Mode or press and hold the Set Up and
Set Down buttons simultaneously for ve (5) seconds to enter the Extended Setup Programming Mode.
Programming a Meter Immediate Regeneration System
Page 11
2. EXTENDED Programming Mode
Regeneration Cycle Step Programming (Display Code 1 – 6)
This Program Step is used to program the Regeneration Cycle step times. The Regeneration Cycle Step
being programmed is displayed in the rst digit of the display. Each display is used to set the duration time in
minutes of that specic step in the Regeneration cycle.
Example:
Cycle Step dF dFFF FLtr
1 10 = Backwash 12 = Fill 10 = Backwash
2 60 = Brine Draw 60 = Brine Making 10 = Rapid Rinse
3 5 = 2nd Backwash 10 = Backwash
10 = Rapid Rinse 60 = Brine Draw
5 12 = Rell 5 = 2nd Backwash
6 10 = Rapid Rinse