EasyManua.ls Logo

Flintec FT-112 - Page 122

Flintec FT-112
170 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 121 of 170
8
Unit change (from first to second unit)
9
Unit change (from second to first unit)
10
Keylock enable
11
Keylock disable
12
Dynamic Start
13
Dynamic Reset
14
M+ key usage
15
Totalization Print (MRC key and Print key)
16
Totalization Cancel.
17
SmartAPP Start
18
SmartAPP Reset
19-23
Not used
24
Basic peak enable
25
Basic peak disable
26
Hold enable
27
Hold disable
40027
R
2
Commands status
0
None
1
Command is processing…
2
Command is successfully.
3
Command failed.
40029
R/W
12
Reserve
40041
R
2
Status of Inputs
Bit
Definition
B0
Input-1
0 Passive
1 Active
B1
Input-2
B2
Input-3
B3
Input-4
40043
R/W
2
Status of Outputs
B0
Output-1
0 Passive
1 Active
B1
Output-2
B2
Output-3
B3
Output-4
B4
Output-5
40045
R/W
2
Basic weighing
Filling
Checkweighing
Classifying
Peak holding
Setpoint 1(High)
Target
Target
Target
Follow
40047
R/W
2
Setpoint 2(High)
Coarse
Low
- - Low
Mid Decr.
40049
R/W
2
Setpoint 3(High)
Fine
High
-Low
End Decr.
40051
R/W
2
Setpoint 4(High)
TareMin
Empty
+High
Stop
40053
R/W
2
Setpoint 5(High)
TareMax
Not used
++High
Alarm
40055
R/W
2
Not used
Empty
Not used
Empty
Empty
40057
R/W
2
Setpoint 1 Low
Only available for Threshold and Window feature.
Refer to sub-block 36-, page 61 to see the availabilities.
40059
R/W
2
Setpoint 2 Low
40061
R/W
2
Setpoint 3 Low
40063
R/W
2
Setpoint 4 Low
40065
R/W
2
Setpoint 5 Low
40067
R
2
Only available for Peak hold application.
Refer to Section 10.4, page 88.
1
st
Peak value
40069
R
2
2
nd
Peak value
40071
R
2
3
rd
Peak value
40073
R
2
4
th
Peak value
40075
R
2
5
th
Peak value