Specifications
12
12.2 Thermal Imaging Specifications
Thermal imaging camera
FLIR Lepton®, microbolometer FPA (focal plane
array)
Image calibration Automatic (with lock-scale option: see Tempera-
ture Scale option from the Main Menu)
Thermal image resolution 160(W) x 120(H) pixels
Spectral response
8~14µm
Field of view 57° horizontal x 44° vertical
Thermal Sensitivity
< 150 mK
Object temperature range 0 to 100 (32 to 212)
Detection Limit Wet area detection @ 10 m (32’): 49 cm
2
(19.7
in
2
)
Thermal frame update rate 9 Hz
Thermal image palettes
Selectable: Iron, Rainbow, White hot, Black hot,
and Arctic
Minimum focus distance 10 cm (4”)
Laser pointer
Visible light Class II, centred on thermal image;
1.0 mW (max. power) Wavelength: 650 ±20nm
12.3 Moisture Measurement Specifications
Internal Pinless Sensor
Measurements
0 to 100 (relative readings)
External Pin-based
Measurements
7% to 30%;
1
Accuracy for 7% to 30% range:
(±1.5% MC);
2
30%-100% (Reference Only)
3
Measurement Resolution 0.1
Pinless Measurement Depth 1.9 cm (0.75 in.) maximum
Pin Moisture Groups Eleven (11) material groups
Response time Pinless mode: 100 ms, Pin mode: 750 ms
1. Maximum specified range is dependent on the fibre saturation point for specific species. Beyond
this point, the reading can only be used as a relative reference value. For more information on fi-
bre saturation please refer to public document ASTM D7438. Accuracy specification is based on
the analysis in J. Fernández-Golfín et al. Actual real-world accuracy depends on a variety of fac-
tors; For more information, refer to public document ASTM D4444, section 6.
2. Accuracy spec. applies to pin probe moisture measurements taken on wood whose temperature
is 20 °C (70 °F). Add 0.1% to the accuracy spec. for each °C below 20 or subtract 0.1 for each °
C above 20.
#NAS100070; r. AB/77165/77326; en-GB