STRADA PAL – MAINTENANCE MANUAL
109/149
8.5.5 Replacing the collection trapdoor closing sensor
8.5.5.1 Preliminary operations
A. Ask a collection operator to perform a first collection of the coins to remove the
coinbox.
B. Perform function 57 (SAO transfer) to forward the financial data to the Parkfolio
server.
C. Ask the collection operator to perform a second collection so that it unlocks the
collection compartment.
D. Open the maintenance door
E. Turn off the terminal
F. Disassemble the collection trapdoor
G. Remove the collection rack
8.5.5.2 Replacement
A. Unplug the sensor cable.
B. Loosen the 2 screws and remove the collection trapdoor closing sensor (1) from the
rack.
Replacing the collection trapdoor closing sensor
8.5.5.3 Installation
Pass the thread behind the rod and make a breakage.