8.9.4 Replacing the electrical equipment
8.9.4.1 Preliminary operations
A. Open the floor fixation trapdoor
B. Turn off the terminal
8.9.4.2 Replacement
A. Remove the ground cable fixed on the trapdoor (1).
B. Remove the ground cable fixed in the power supply compartment (2).
C. Take the electrical equipment out of the power supply compartment.
D. Unplug the fast connection (3) located on the electrical equipment.
E. Remove the electrical equipment.
Replacing the electrical equipment
8.9.4.3 Installation
A. Screw the 4 cap nuts on the 4 studs located in the power supply compartment.
B. Connect the electrical equipment to the main board using the fast connection.
C. Place the electrical equipment on the 4 studs located in the power supply
compartment.
D. Connect the electrical equipment to the stud located at the bottom of the power
supply compartment; stack the components in the following order: washer – strand
(intended to connect the door) – washer – housing protective earth strand – washer
– nut.
E. Finish the connection of the trapdoor to the earth; stack the components in the
following order: washer – trapdoor protective earth strand – washer – nut.
F. Check that the door protective earth strand goes through its dedicated slot on the
trapdoor.
8.9.4.4 End of procedure
A. Turn on the terminal
B. Close the maintenance door