FW-E115-P-M_v0203_03_EN.docx
Communication (option)
Function
Reading display information, reading / writing all configuration settings and data log extraction.
Type CB
Modbus RTU - RS232
Type CH
Modbus RTU - RS485 2-wire, bus termination without resistor for low power solutions
Type CU
USB communication incl. Ex d plug
Requires ¾”NPT or M25 side entry thread.
Type CX
No communication, remote configuration possible with accessory cable ACE02.
Speed [baud]
1200 - 2400 - 4800 - 9600 - 9600HP - 19200 - 38400
Addressing
maximum 247 addresses.
Operational
Operator functions
Displayed information
Differential total and/or flow rate
Differential total and non-resettable accumulated total
Total A forward flow
Total B reverse flow
Differential total can be reset to zero by pressing the CLEAR-key twice.
Speedometer flowrate: differential, forward flow or reverse flow
Current Day total, previous day total and 15 historical day totals
Total
Digits
7 digits.
Unit
L, m3, US gal, igal, cf, Oil bbl, kg, ton, US ton, lb or none.
Decimals
0 - 1 - 2 or 3.
Total can be reset to zero.
Daily totals
Digits
7 digits.
Unit / decimals
According to selection for total
Contract hour
0:00 23:00, settable per whole hour
Current day total
Running total, started at zero after the last contract hour
Previous day total
Fixed total, copied from current day total at the last contract hour
Historical day totals
The last 15 previous day totals are stored and can be reviewed on the display
Current day total cannot be reset to zero.
Accumulated total
Digits
11 digits.
Unit / decimals
According to selection for total.
Function
Differential total, total A(forward flow) and total B (reverse flow)
Accumulated total cannot be reset to zero.
Flow rate
Digits
7 digits.
Units
mL, L, m3, mg, g, kg, ton, US ton, US gal, igal, Oil bbl, lb, cf, rev, none, scf, nm3, nL or p.
Bargraph speedometer
20 blocks, each block is 5% of total span
Decimals
0 - 1 - 2 or 3.
Time units
/sec - /min - /hr - /day.
Function
Differential flow

Other manuals for Fluidwell E119-P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluidwell E119-P and is the answer not in the manual?

Fluidwell E119-P Specifications

General IconGeneral
BrandFluidwell
ModelE119-P
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals