ACCESSORIES
PROBE
ACCESSORIES
600-19. Temperature Probe,
Celsius
80T-150C
600-20.
The
80T-150C
Temperature
Probe
converts
your instrument into a direct-reading
(1
mV
de/degree)
Celsius thermometer.
It
is
suited for surface, ambient, and
some liquid measurements. A rugged, fast-responding
probe tip with a
350V
de standoff capability makes the
80T-150C a versatile and easy-to-use temperature probe.
600-21. Temperature Probe, Fahrenheit 80T-150F
600-22.
The 80T-150F
is
the as the 80T-150C
except the
80T-150F
is
set to read in degrees Fahrenheit.
600-23.
Current Transformer
801-600
600-24.
The
Model 80I-600
Current Transformer
extends the maximum 2A ac current measuring limit
of
the
8050A
to a maximum of
600A.
The clamp-on
transformer design allows measurements to
be
made
without breaking the circuit under test. Because of a high-
efficiency, quadrature-type
of
winding, wire
size
and
location of the conductor within the transformer jaws do
not affect the accuracy
of
the current measurement.
600-25. Current Shunt
SOJ-10
600-26.
The Model
801-10
Current
Shunt extends the
current measuring capability
of
your meter to 1
OA
continuous
(20A
for periods not exceeding I minute) de
to
10
kHz
at
an accuracy of
±
0.25%.
600-27.
High
Voltage
Probe
SOK-6
600-28.
The Model
80K-6
High Voltage
Probe extends
the voltage measuring capability
of
your meter up to 6
kV.
Internally, the probe contains a
1000:
I divider. The
divider
is
made with special metal film resistors with
matched temperature coefficients, providing the probe
with excellent accuracy and stability characteristics. Also,
the very high input impedance
(75
Mn)
minimizes circuit
loading, thus contributing to measurement accuracy. The
plastic housing provides for operator safety while
measuring potentially dangerous voltages.
600-29.
High
Voltage
Probe
SOK-40
600-30.
The Model80K-40
High Voltage
Probe
extends
the voltage measuring capability of your meter up to
40
kV.
Internally, the probe contains a
1000:1
divider. The
divider
is
made with special metal
film
resistors with
matched temperature coefficients, providing the probe
with excellent accuracy and stability characteristics. Also,
the very high input impedance
(1000
Mn)
minimizes
circuit loading, thus contributing to measurement
accuracy. The plastic housing provides for operator
safety while measuring potentially dangerous voltages.
600-31.
RF
Probe 83RF
600-32.
The 83RF converts the
8050A into a high
frequency,
100
kHz to l
00
MHz, ac voltmeter over a
600-4
voltage range
of0.25V
to
30V
rms. The DC output of the
probe
is
calibrated to be equivalent to the rms value of a
sine
wave.
The probe
is
used with the DC V function and
ranges
of
the
8050A.
600-33.
RF
Probe 85RF
600-34.
The 85RF converts the 8050A
into a high
frequency,
100
kHz to
500
MHz, ac voltmeter over a
voltage range
of
0.25V to
30V
rms. The de output of the
probe
is
calibrated to be equivalent to the rms value of a
sine wave. The probe
is
used with the DC V function and
ranges of the
8050A.
600-35. DC/AC Current Probe
Y8100
600-36.
The Model
Y8100
DC/
AC Current
Probe
is
a
battery-powered (four AA cells) Hall-Effect probe for use
with the
8050A
to take de, ac, or composite (ac or de)
current measurements. The clamp-on jaws on the
Y8100
allow it to clamp around conductors up to 3
I
4-inch in
diameter. The pistol shape allows safe, easy, one-hand
operation when making current measurements. The
Y8100
has detachable leads and
is
used in conjunction
with the voltage inputs
of
the
8050A.
600-37. AC Current Transformer
Y8101
600-38.
The Model
Y8101
Current Transformer(Figure
1)
is
a small clamp-on current transformer designed to
extend the current measuring capability of an ac current
meter up to l
50A. A clamp-on coil designed into the
probe allows measurements to be made without breaking
the
circuit under test. This coil serves
as
the secondary
of
a
1:1000
transformer. The current-carrying conductor
being measured serves
as
the primary.
600-39. Deluxe
Test Lead
Set
(safety designed)
Y8134
600-40.
The Model Y8134 Deluxe Test Lead Set
includes two probes with sharp tips, two alligator clips,
two spade lugs, and a spring-loaded hook tip. Banana
plugs are recessed in
an
insulating shield.
Probes
contain
finger guards for additional protection.
600-41. Slim-Flex Test Leads Y8140
600-42.
The Model
Y8140
Test Lead
Set
(Figure
1)
consists of one red and one
black60-inch
(l.52 meter)test
lead, each with a standard banana plug on one end and an
extendible tip probe on the other end. This flexible
metallic tip conductor may be extended up to
2-1
/2
inches, and
is
insulated to within l / l
0
of an inch of its tip.
This insulation reduces the chance
of
creating an
inadvertent short circuit while using the probes in their
extended configuration. Although the
Y8140
test leads
are intended for measuring voltages, they may also
be
used for measuring low currents.