INTRODUCTION
SPECIFICATIONS
MODEL
C86
Y8205
M00-200-611
M00-200-612
M00-200-613
80T-H
80T-150C
80T-150F
801-600
ELECTRICAL
Table
1-1.
8050A
Accessories
DESCRIPTION
MODEL
DESCRIPTION
Ruggedized
Carrying Case
80J-10
Current Shunt
Soft Carrying Case
BOK-6
High
Voltage Probe
Offset Mounting Kit
80K-40 High
Voltage
Probe
Center
Mounting Kit
83-RF
RF
Probe
Dual
Mounting Kit
85-RF
RF
Probe
Touch-Hold
Probe
Y8100 DC/AC Current
Probe
Temperature Probe,
Celsius
Y8101
AC Current
Transformer
Temperature Probe, Fahrenheit
Y8134
Deluxe
Test Lead
Set
(safety designed)
Current Transformer
Y8140
Slim-Flex
Test Leads
Table
1-2.
8050A
Specifications
The electrical
specifications given
apply
for
an
operating
tem-
perature
of
18°C
to
28°C (64.4°
Fto
82.4°
F),
relative
humidity up to
90%,
and a 1-year
calibration cycle.
Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DC volts, AC volts (linear
and dB), DC
current,
AC
current,
resistance, diode test, conductance, relative.
DC
Voltage
RANGE
RESOLUTION
ACCURACY
for
1-Year
±200 mV
10µV
±2V
100µV
±20V
1 mV
±(0.03%
of
reading
+2
digits).
±200V
10
mV
±1000V
100mV
INPUT IMPEDANCE . . . . . . . . . . . . . . . . . . . .
10
MO
in
parallel
with
<100
pF,
all
ranges.
NORMAL MODE REJECTION RATIO
. . .
>60
dB at
60
Hz
or
50
Hz.
COMMON MODE REJECTION RATIO
.
. .
>90
dB at
de,
50
Hz or
60
Hz
(1
kO
unbalanced)
(>120 dB available on request)
COMMON MODE VOLTAGE (MAXIMUM)
500V
de or peak ac
RESPONSE TIME TO
RATED
ACCURACY
1 second maximum
MAXIMUM INPUT . . . . . . . . . . . . . . . . . . . . . .
1000V
de
or
peak ac continuous
(less
than
10
seconds duration on
both the
200
mV
and
2V
ranges).
*DC voltages can
also
be
measured using the dB mode with
.01
dB
resolution between
5%
of
range and
full range.
1-2