Testing Twisted Pair Cabling
17
Short on Twisted Pair Cabling
Figure 9 shows a short between wires 5 and 6. The shorted
wires flash to indicate the fault. The cable length is 75.4 m.
Note
When there is a short, the far-end adapter and the
mapping of the unshorted wires are not shown.
Typical Causes of Shorts
Damaged connector.
Damaged cable.
Conductive material stuck beween pins at connector.
Improper connector termination.
Wrong application for cable.
EKG06.EPS
Figure 9. Short on Twisted Pair Cabling