Fluke 192B - 196B/C - 199B/C
Users Manual
96
Dual Input Oscilloscope
Isolated Inputs A and B (Vertical)
Bandwidth, DC Coupled
FLUKE 199B/C ....................................200 MHz (-3 dB)
FLUKE 196B/C ....................................100 MHz (-3 dB)
FLUKE 192B..........................................60 MHz (-3 dB)
Lower Frequency Limit, AC Coupled
with 10:1 probe .........................................<2 Hz (-3 dB)
direct (1:1).................................................<5 Hz (-3 dB)
Rise Time
FLUKE 199B/C .................................................... 1.7 ns
FLUKE 196B/C .................................................... 3.5 ns
FLUKE 192B........................................................ 5.8 ns
Analog Bandwidth Limiters ................20 MHz and 10 kHz
Input Coupling.......................................................AC, DC
Polarity....................................................Normal, Inverted
Sensitivity Ranges C versions
with 10:1 probe ..............................20 mV to 1000 V/div
direct (1:1)..........................................2 mV to 100 V/div
Sensitivity Ranges B versions
with 10:1 probe ..............................50 mV to 1000 V/div
direct (1:1)..........................................5 mV to 100 V/div
Trace Positioning Range ............................... ±4 divisions
Input Impedance on BNC
DC Coupled........................1 M (±1 %)//15 pF (±2 pF)
Max. Input Voltage
with 10:1 probe.................600 V CAT III; 1000 V CAT II
direct (1:1) ................................................ 300 V CAT III
(For detailed specifications, see “Safety”)
Vertical Accuracy ......................±(1.5 % + 0.04 range/div)
2 mV/div: ....±(2.5 % + 0.08 range/div)
For voltage measurements with 10:1 probe, add probe
accuracy, see section ‘10:1 Probe’ on page 109.
Digitizer Resolution ..................... 8 bits, separate digitizer
for each input
Horizontal
Maximum Time Base Speed:
FLUKE 196B/C, 199B/C.................................... 5 ns/div
FLUKE 192B ................................................... 10 ns/div
Minimum Time Base Speed (Scope Record) ..... 2 min/div
Real Time Sampling Rate (for both inputs simultaneously)
FLUKE199B/C:
5 ns to 2 µs /div ....................................up to 2.5 GS/s
5 µs to 120 s/div .............................................20 MS/s
FLUKE 196B/C:
5 ns to 2 µs /div .......................................up to 1 GS/s
5 µs to 120 s/div .............................................20 MS/s