42
Keep the Imager attached to the charger until the battery condition icon shows a full charge. If you
remove the Imager from the charger before a full charge shows, it can have a reduced run-time.
Note
When the battery is connected to ac power or the unit is in video mode, the Sleep Mode/Auto Off
feature is disabled automatically.
Optional 12 V Vehicle Charger
1. Connect the 12 V adapter into the 12 V accessory socket of the vehicle.
2. Connect the output to the ac power socket of the Imager.
3. Charge until the indicator shows full on the screen.
4. Disconnect the 12 V adapter and Imager when battery is fully charged.
Caution
To prevent damage to the Imager, remove it from the dc car charger before you start or
jump start the vehicle.
Always operate in the specified temperature range.
Do not store the batteries in extreme cold environments.
Do not attempt to charge the batteries in extreme cold environments.
 Caution
Do not incinerate the Product and/or battery.
Radio Frequency Data
See Table 13 for instructions on how to access digital copies of the Certificate IDs on the Imager.
To view the Radio Frequency Data Class B Instruction Sheet, visit
http://us.fluke.com/usen/support/manuals
and search for 4409209.
General Specifications
Ti200 Ti300 Ti400 Ti450 Ti450SF6 Ti480
Temperature
Operating -10 °C to +50 °C (+14 °F to +122 °F)
Storage -20 °C to +50 °C (-4 °F to +122 °F) without batteries
Relative Humidity 10 % to 95 % non-condensing
Altitude
Operating 2000 m
Storage 12 000 m
Display 8.9 cm (3.5 in) touchscreen diagonal landscape color VGA LCD with backlight