14
Temperature Measurement
All objects radiate infrared energy. The quantity of energy radiated is based on
the actual surface temperature and the surface emissivity of the object. The
Product senses the infrared energy from the surface of the object and uses this
data to calculate an estimated temperature value. Many common objects and
materials such as painted metal, wood, water, skin, and cloth are very good at
radiating energy and it is easy to get relatively accurate measurements. For
surfaces that are good at radiating energy (high emissivity), the emissivity
factor is 90 % (0.90). This simplification does not work on shiny surfaces or
unpainted metals as they have an emissivity of <60 % (0.60). These materials
are not good at radiating energy and are classified as low emissivity. To more
accurately measure materials with a low emissivity, an emissivity correction is
necessary. Adjustment to the emissivity value will usually allow the Product to
calculate a more accurate estimate of the actual temperature.
Note
Surfaces with an emissivity <0.60 make reliable and consistent
determination of actual temperatures problematic. The lower the
emissivity, the more potential error is associated with the temperature
measurement calculations of the Product, even when emissivity and
reflected background adjustments are attempted and performed
properly.
Warning
To prevent personal injury, see emissivity information for actual
temperatures. Reflective objects result in lower than actual
temperature measurements. These objects pose a burn hazard.
Shop for Fluke products online at:
1.877.766.5412
www.MyFlukeStore.com

Other manuals for Fluke VT04

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke VT04 and is the answer not in the manual?

Fluke VT04 Specifications

General IconGeneral
TypeInfrared environment thermometer
Purpose-
PlacementHand
Display typeDigital
Product colorBlack, Yellow
Display form factorRectangular
Accuracy2 °C
Clock functionYes
Spectral response6.5 - 14 µm
Temperature measurement range-10 - 250 °C
Temperature measurement unitsF, °C
Power sourceBattery
Battery voltage3.6 V
Number of batteries supported1
CertificationEN 61326:2006, IEC/EN 61010-1:2010
Operating altitude0 - 2000 m
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)-5 - 45 °C
Operating relative humidity (H-H)10 - 90 %
Battery life8 h
Weight and Dimensions IconWeight and Dimensions
Depth55 mm
Width75 mm
Height210 mm
Weight350 g