19
Exit Delay
By default, when you arm the system in Out Mode, the
Main Panel will count down with an Exit Delay in order to
give you time to leave before the system is armed. e Out
light will be ashing while the Exit Delay is counting down.
e default Exit Delay is 30 seconds, and it can be adjusted
from 0 to 90 seconds.
To change the Exit Delay time, enter Programming Mode
(page 7), then...
27 * [2-digit number] #
For example, to set the Exit Delay to 10 seconds, the com-
mand would be...
27 * 10 #
Entry Delay
e Entry Delay gives you time to go to the Main Panel
and disarm the system before the alarm is triggered.
To change the Entry Delay time, enter Programming Mode
(page 7), then...
28 * [2-digit number] #
Each individual Zone can have Entry Delay enabled or dis-
abled. See the Zone Settings section for more information.