63 PB
TROUBLESHOOTING
COMPLAINT CAUSE SOLUTION
Electronic control
board does not turn unit off
Compressorrelaycontactsstuck Replaceelectroniccontrolboard
Incorrectwiring Refer to appropriate wiring diagrams
Unitundersizedforareatobecooled Refertoindustrystandardsizingchart
Defectivethermistor Replacethermistororelectroniccontrolboard
Compressor runs for short periods
only.
Incorrectwiring Refer to appropriate wiring diagram
Shortedorincorrectcapacitor Testcapacitorandreplaceifneeded.
Restrictedorlowairowthrough
condensercoilorevaporatorcoil
Checkforproperfanspeedorblockedcoils.
Correctasneeded.
Compressor running abnormally hot
Checkforkinkeddischargelineorrestricted
condenser.Refrigerantovercharge.Checkam-
perage,connections.
Unit does not turn on
No power
Checkpowersupply.CheckLCDIplug.Check
wireconnections.Checkifpanelislocked.
Incorrectwiring Refer to appropriate wiring diagram
Defectivethermistor Replacethermistororelectroniccontrolboard
Noisy operation
Poorly installed
Refer to Installation Manual for proper instal-
lation
Fanbladestrikingchassis Reposition - adjust motor mount
Compressor vibrating
Checkthatcompressorgrommetshavenot
deteriorated.Checkthatcompressormounting
parts are not missing
Improperlymountedorloosecabinet
parts refrigerant tubes
Checkassembly&partsforlooseness,rubbing
&rattlingpipes,etc.
WaterLeaksintoRoom
Evaporatordrainpanoverowing Cleanobstructeddraintrough
Condensation forming underneath
base pan
Evaporatordrainpanbrokenorcracked.Reseal
orreplace.Nochassisgasketinstalled.Install
chassisgasket
Poor installation resulting in rain en-
tering the room
Checkinstallationinstructions.Resealasre-
quired
Condensationondischargegrille
louvers
Dirtyevaporatorcoil.Cleancoils(SeeRoutine
Maintenance)Environmentalphenomena:point
supplylouversupward.Putonhighfan.
Chassisgasketnotinstalled Installgasket,perInstallationmanual
Downward slope of unit is too steep
inward
Refer to installation manual for proper instal-
lation
Tips continued