Lubricate the stoker bearings [~1000 B/every six months]
FET
T
3x
Lubricate stoker bearings with three grease gun strokes per grease nipple
Check chain and sprockets [~1,000 operating hours / every six month]
Kettenspanner nicht einstellbar!! (prl, 10.07.2020)
Loosen the screw at the top of the cover and remove the cover by pulling it
downwards
Check chain and sprockets for wear, replace if necessary
Grease chain and sprockets using suitable lubricant
Check chain for tension
Clean the combustion chamber [~2500 Bh /yearly]
Open the insulated door
Pull out the ash container
Open the combustion chamber door by turning the Allen wrench (90°)
Use the Allen wrench included (A – AF 13 mm)
Allen wrench stored in tool clip (B)