114
Display during normal operation
When there is an error in one of the
two power modules, the display
flashes between ‘STATE’ and the
corresponding status message
(e.g. ‘STATE 515’)
and
‘ENTER’
- Press the ‘Enter key twice
Status Mes-
sages for a
Fronius IG
Plus with
Several Power
Modules
If an error occurs in a Fronius IG Plus with more than one power module,
then a specific status message will be displayed.
Status messages can also be accessed even when there is no fault.
Information on reviewing the status can be found in ‘The Setup Menu’
section of this manual.
- The power module status dis-
play appears ‘STATEPS
- Press the ‘Enter key
Additional information can be
found in ‘The Setup Menu’
section, STATEPS Menu Option

Table of Contents