EasyManua.ls Logo

Fronius IG Plus 35 - Scrolling through Menu Options; Menu Options in the Setup Menu

Fronius IG Plus 35
157 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
89
Scrolling
through Menu
Options
(1) (2) (1) (2)
Example: ‘STANDBY menu option
Example: ‘CONTRAST’ menu option
STANDBY
Manual activation / deactivation of Standby operation using the ‘Enter key
Unit -
Setting range Enter
Factory setting ‘Standby’ deactivated
- The power electronics are switched off in standby mode. No power is
fed into the grid.
- The Operating Status LED flashes orange.
- The orange flashing LED goes off after dusk.
- After sunrise the following day, power being fed into the grid is resu-
med automatically (LED will light up green after the startup phase).
- When the LED is flashing orange, the grid feed can be resumed at
any time (deactivate ‘StandBY’).
CONTRAST
Adjusts the contrast on the LCD display
Unit -
Setting range 0 - 7
Factory setting 7
Because contrast is temperature-dependent, changing environmental
conditions can require the setting of the ‘Contrast’ menu option.
Menu Options
in the Setup
Menu
1. Open the setup menu
2. Scroll through the available menu options using the ‘Up’ (1) and
‘Down’ (2) keys

Table of Contents

Related product manuals