Loading...
139
Fronius IG
Plus 120
Input data
MPP voltage range 230 - 500 V DC
Max. input voltage 600 V DC
(at 1000 W/m²/ -10 °C (14 °F) in an open circuit)
Max. input current 45.78 A DC
Output data
Nominal output power (P
nom
) 10 kW
Max. output power 10 kW
Nominal mains voltage 3 ~ NPE 400 V, +10 / -15 %
1)
Nominal output current (three phase) 15.2 / 14.5 A AC
Nominal frequency 50 - 60 Hz
1)
Harmonic distortion < 3.5 %
Power factor cos phi 1
Max. permitted mains impedance Zmax at PCC
2)
none
General data
Maximum efficiency 96 %
Europ. max. efficiency 95.5 %
Power consumption at night < 1 W
Cooling Controlled forced ventilation
Protection class IP 44
Dimensions l x w x h 244 x 434 x 1221 mm (9.6 x 17.1 x 48.1 in)
Weight 49 kg (108 lb)
Permissible ambient temperature -20 °C - +50 °C (-4 °F - +122 °F)
(with 95% rel. humidity)
EMC emission class B
Protective equipment
DC insulation measurement Warning when R
ISO
< 500 kOHM
DC overvoltage protection integrated
Protection against reversed polarity integrated
Manifestation of DC overload Operating point shift