EasyManua.ls Logo

Fronius IG Plus 35 - Fronius IG Plus 150; Explanation of Footnotes

Fronius IG Plus 35
157 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
140
Fronius IG
Plus 150
Input data
MPP voltage range 230 - 500 V DC
Max. input voltage 600 V DC
(at 1000 W/m²/ -10 °C (14 °F) in an open circuit)
Max. input current 54.9 A DC
Output data
Nominal output power (P
nom
) 12 kW
Max. output power 12 kW
Nominal mains voltage 3 ~ NPE 400 V, +10 / -15 %
1)
Nominal output current (three phase) 18.2 / 17.4 A AC
Nominal frequency 50 - 60 Hz
1)
Harmonic distortion < 3.5 %
Power factor cos phi 1
Max. permitted mains impedance Zmax at PCC
2)
none
General data
Maximum efficiency 96 %
Europ. max. efficiency 95.5 %
Power consumption at night < 1 W
Cooling Controlled forced ventilation
Protection class IP 44
Dimensions l x w x h 244 x 434 x 1221 mm (9.6 x 17.1 x 48.1 in)
Weight 49 kg (108 lb).
Permissible ambient temperature -20 °C - +50 °C (-4 °F - +122 °F)
(with 95% rel. humidity)
EMC emission class B
Protective equipment
DC insulation measurement Warning when R
ISO
< 500 kOHM
DC overvoltage protection integrated
Protection against reversed polarity integrated
Manifestation of DC overload Operating point shift
Explanation of
footnotes
1)
The values provided are standard values. Upon request, the Fronius
IG Plus can be customized to the respective country.
*)
PCC = interface to the public grid

Table of Contents

Related product manuals