Indications/Controls on the Device
1x WPS
2x ACCESS POINT
3x BOOST
WPS (Wi-Fi Protected Setup) is opened
for 2 minutes or until successful pairing
with the router. By pressing the WPS
button the router, the WLAN password is
transmitted to the Ohmpilot.
WLAN access point is activated for 30
minutes so that settings can be implement-
ed on the Ohmpilot via the Fronius Solar
web app.
Boost mode - dimmer level is activated for
4 hours at 100%, L2 and L3 are switched
through. This may result in electricity being
sourced from the grid.
Ohmpilot is returned to standard operating
mode, boost mode, access point or WPS
are deactivated.
No power supply to the
Ohmpilot
The faster the ashing frequency, the
greater the heat output. At 0 W heat output
the LED ashes slowly, at full output it
ashes quickly.
The output from the heating element is
measured and it is detected whether a
1-phase or 3-phase heating element is
connected.
Target temperature undercut or legionella
prevention system active (full heat output).
No connection
WPS (Wi-Fi Protected Setup) open
WLAN access point open
Connection with network
No error
No connection to the inverter
Temperature measurement faulty
Heating element faulty
Ohmpilot faulty
Target temperature not reached
Press 1x
Press 2x
Press 3x
Press
again
Unlit
Flashing green
Flashing green 2x
Steady green
Heater indication
Green LED
Unlit
Flashing blue 1x
Flashing blue 2x
Steady blue
Connection indica-
tion LAN / WLAN
Blue LED
Unlit
Flashing red 1x
Flashing red 2x
Flashing red 3x
Flashing red 4x
Flashing red 5x
Error indication
Red LED
A detailed description of the error is provided in Solar Web.