Fronius Ohmpilot - Location Selection Criteria

Fronius Ohmpilot
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
EN
Wiring Diagram
NC W NO OUT N
L1 L2 L2L3 N N L3 N
LAN
RS485
PT1000
D+ D- -
R2
R3
G B R
1 2 3
4
5 7
8
9 10
11 12
6
7
1
Green LED
Connection terminal for PT1000
Temperature sensor
Spring balancer 0.2 - 1.5 mm
2
8
2
Blue LED
INPUT - grid supply 1x 230 V or 3x 230 V
Spring balancer 1.5 - 1.5 mm
2
3
Red LED
4
Button
5
Ethernet RJ45, at least CAT5,
screened
6
Modbus RTU (default address 40)
Spring balancer 0.2 - 1.5 mm
2
max. 1000 m, screened and twisted
9
OUTPUT - L2 heating element
Spring balancer 1.5 - 2.5 mm
2
10
OUTPUT - L3 heating element
Spring balancer 1.5 - 2.5 mm
2
11
Multifunctional relay output
(see application examples)
variable max. 13 A resistive load
Spring balancer 1.5 - 2.5 mm
2
WARNING! If signal cables are connected,
the individual wires must be bound togeth-
er with a cable tie directly upstream of the
terminal. This prevents any wire making
contact with dangerous voltages if it works
loose.
12
OUTPUT - heating element continuously
adjustable up to 3 kW
NOTE! Phase and neutral conductors
must not be mixed up. Residual cur-
rent-operated circuit breaker is triggered.