Error List:
Sending of Errors
• Errors are saved in the Datamanager 2.0 and can be sent via Solar Web.
• Possible error outputs (as of 07/12/2015):
Code
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
Description
Heating element 1 faulty -
short circuit L1
HE 1 - overload on L2
HE 1 - overload on L3
HE 1 faulty - L1 highly resistive
HE 1 faulty - L2 highly resistive
HE 1 faulty - L3 highly resistive
HE 2 faulty -
short circuit L1
HE 2 - overload on L2
HE 2 - overload on L3
HE 2 faulty - L1 highly resistive
HE 2 faulty - L2 highly resistive
HE 2 faulty - L3 highly resistive
Relay 2 faulty
Relay 3 faulty
TS short circuit
TS not connected or faulty
60 °C for legionella prevention
could not be achieved within 24
hours.
Target temperature could not
be achieved within 5 hours
ES could not achieve target
temperature within 5 hours.
Cause
The load on L1 is higher than 3
kW. Short circuit on L1.
Current on L2 is greater than 16 A.
Current on L3 is greater than 16 A.
No current owing through L1/L2/
L3. L1/L2/L3 of HE 1 faulty. Phase
L1/L2/L3 interrupted.
The load on L1 is higher than 3
kW. Short circuit on L1.
Current on L2 greater than 16 A.
Current on L3 greater than 16 A.
No current owing through L1/L2/
L3. L1/L2/L3 of HE 2 faulty. Phase
L1/L2/L3 interrupted.
Relay R2/R3 sticking.
TS input resistance less than 200
Ohm. No PT1000 TS connected.
TS faulty.
No TS connected
(Input resistance greater than
2000 Ohm). TS is activated
(should be deactivated). TS cable
faulty. TS faulty. No PT1000 TS
connected.
ES is switched off/faulty. (922
only). TS was incorrectly installed.
Heating system is incorrectly
dimensioned (excessive hot water
consumption, etc.) HE/TS faulty.
ES switched off/faulty. ES not con-
nected to Ohmpilot. TS incorrectly
installed. Heating system incor-
rectly dimensioned (excessive hot
water consumption, etc.) TS faulty.
Solution
Check heating element 1.
Check wiring.
Check HE 1 and replace if
necessary.
Check L1/L2/L3. Check L1/
L2/L3 connections.
Check HE 2.
Check wiring.
Check HE2 and replace if
necessary.
Check L1/L2/L3. Check L1/
L2/L3 connections.
Replace Ohmpilot.
Check cable and connections
on TS cable. Replace TS.
Connect TS to device. Deac-
tivate TS via the website (if
no sensor is required). Check
TS cable. Replace TS.
Switch on ES (922 only).
Install TS above the HE (in
protective tube). Deactivate
legionella prevention via the
website. Replace HE/TS.
Switch on ES. Connect ES
to relay 1. Install TS above
the heat battery of the ES.
Check the target temperature
setting. Replace TS.
HE=Heating element TS=Temperature sensor I=Inverter ES=External source (e.g. gas-red heating)