WiFi Access Point
[not available]
Displayed if there is no system monitoring present on
the inverter.
DATCOM Checking data communications, entering the inverter number, protocol settings
Setting range Status / inverter number / protocol type
Status
Indicates data communication is taking place via Fronius Solar Net or that a
data communications error has occurred
Inverter number
Sets the number (= address) of the inverter in a system with several inverters
Setting range 00 - 99 (00 = inverter address 100)
Factory setting 01
IMPORTANT! If a number of inverters are linked together in a data communic-
ations system, assign a unique address to each one.
Protocol type
Specifies the communications protocol to be used to transfer the data:
Setting range Solar Net / Interface *
Factory setting Fronius Solar Net
* The protocol type "Interface" only functions when there is no Datamanager
card in the inverter. All Fronius Datamanager cards should be removed from
the inverter.
USB Running firmware updates or saving detailed information from the inverter to the
USB flash drive
Setting range Safely remove hardware / Software update / Logging in-
terval
Safely remove hardware
To remove a USB flash drive from the USB A socket on the plug-in data commu-
nications card without losing any data.
The USB flash drive can be removed:
-
If the OK message appears
-
when the "Data transfer" LED stops flashing or comes on steady
Software update
To update the inverter firmware using a USB flash drive.