The Basic menu
General The Basic menu is used to set the following parameters, which are important for
installing and operating the inverter:
-
DC operating mode
-
Fixed voltage
-
MPPT1 / MPPT2 start voltage
-
USB logbook
-
Event counter
-
Grounding mode / grounding
monitoring
-
Insulation settings
-
TOTAL reset
Accessing the
Basic menu
1
Press the "Menu" key
The menu level appears.
2
Press the unassigned "Menu / Esc" key
5 times
"Access Code" is displayed in the "CODE"
menu; the first digit starts flashing.
3
Enter the code 22742: Use the "Plus" and
"Minus" keys to select a value for the
first digit of the code
4
Press the "Enter" key
The second digit flashes.
5
Repeat steps 3 and 4 for the second,
third, fourth and fifth digits of the access
code until...
the selected code starts flashing.
6
Press the "Enter" key
The Basic menu appears.
7
Use the "Plus" and "Minus" keys to select the desired entry
8
Press the "Enter" key to open the desired menu item
9
Press the "Esc" key to exit the Basic menu