Product name Benedict LS32 E 7798
Rated insulation
voltage
1500 V
DC
Rated impulse with-
stand voltage
8 kV
Suitability for insula-
tion
Yes, DC only
Utilisation category
and / or PV utilisa-
tion category
As per IEC/EN 60947-3 utilisation category DC-PV2
Rated short-time
withstand current
(Icw)
Rated short-time withstand current (Icw): 1000 A for 2 poles; 1700 A for 2 +
2 poles
Rated short-circuit
making capacity
(Icm)
Rated short-time withstand current (Icm): 1000 A for 2 poles; 1700 A for 2
+ 2 poles
Rated breaking capa-
city
Rated
operating
voltage
(Ue)
[V d.c.]
Rated
operating
current
(Ie)
[A]
1P
I(make)
/
I(break)
[A]
1P
Rated
operating
current
(Ie)
[A]
2P
I(make)
/
I(break)
[A]
2P
Rated
operating
voltage
(Ie)
[A]
2 + 2P
I(make)
/
I(break)
[A]
2 + 2P
≤ 500 14 56 32 128 50 200
600 8 32 27 108 35 140
700 3 12 22 88 22 88
800 3 12 17 68 17 68
900 2 8 12 48 12 48
1000 2 8 6 24 6 24
Applicable
standards and
guidelines
CE mark
The devices comply with all the requisite and relevant standards and guidelines
that form part of the relevant EU Directive, and are therefore permitted to dis-
play the CE mark.
Circuit to prevent stand-alone operation
The inverter has an approved circuit to prevent stand-alone operation.
Grid failure
The standard measurement and safety procedures integrated into the inverter
ensure that in the event of a grid failure, the feed-in of energy is immediately in-
terrupted (e.g. switch-off by the energy supplier or damage to lines).