Fronius Primo 3.0-1 3.5-1 3.6-1
Permissible humidity 0 - 100%
EMC emission class B
DC / AC overvoltage category 2/3
Inverter topology Non-insulated transformerless
Voltage classification
Decisive Voltage Classification
(DVC rating)
AC DVC-C
DC DVC-C
Data DVC-A
Protection devices
DC isolation measurement
Warning/shutdown
2)
at R
ISO
< 1 MOHM
Manifestation of DC overload Operating point shift, power limiter
DC disconnector Integrated
Active anti-islanding method Frequency conversion method
Fronius Primo 4.0-1 4.6-1 5.0-1
Input data
MPP voltage range 210 - 800 V 240 - 800 V 240 - 800 V
Max. input voltage
at 1000 W/m²/14 °C in an open circuit
1000 V
Max. input current (MPPT 1 / MPPT 2) 12.0 A
Max. short circuit current of the solar modules 18.0 A
Max. inverter backfeed current to the array
3)
18.0 A
Output data
Rated power (P
nom
) 4000 W 4600 W 5000 W
Max. output power 4000 W 4600 W 5000 W
Rated apparent power 4000 VA 4600 VA 5000 VA
Nominal grid voltage 1 ~ NPE 220 / 230 / 240 V
Min. grid voltage
150 V
1)
Max. grid voltage
270 V
1)
Max. output current 18.3 A 21.1 A 22.9 A
Nominal frequency
50 / 60 Hz
1)
Total harmonic distortion < 5%
49
EN