Loading...
Fitting the clamping system for welding torches
with internally routed coolant lines
Tools required
-
Torx® screwdriver, TX25
-
3 mm & 5 mm Allen key
Removing the
existing clamp-
ing system
2
1
1
1
1
1
1
Undo the 5 Allen screws
size 3 mm
2
Remove the housing cover
3
3
4
3
Undo the 2 Allen screws
size 5 mm
4
Remove the 3-part clamping
device element