Manually checking the cleaning device functions
Safety
WARNING!
For the following tasks, the cleaning device must be supplied with compressed
air. This results in danger from the rotating cleaning cutter, cleaning motor mov-
ing up/down, gas nozzle clamping device moving out/in, flying parts (chips,
etc.), compressed air/parting agent mixture escaping from the parting-agent in-
jection nozzle.
This can result in serious injury and damage to property.
Keep your body, especially your hands, face, hair, any objects and all clothing
awayfrom the cleaning cutter, cleaning motor, lifting device, gas nozzle
clamping device,wire cutter and parting-agent injection nozzle..
Wear ear protection!
Wear protective goggles with side protection.
Checking func-
tions manually
NOTE!
When the slot for the "Lifting device up/down", "Spray in parting agent" and
"Clamp gas nozzle/Cleaning motor on" screws is positioned horizontally, func-
tion is deactivated.
1
Disconnect the cleaning device from the robot control
2
Establish a compressed air supply to the cleaning device
The following must be checked when the functions are being performed:
-
function of the gas nozzle clamping device (gas nozzle clamping device ex-
tends/retracts)
-
function of the cleaning motor (cleaning motor OFF/ON)
0
1
2
1
Clamp gas nozzle/cleaning motor on
3
1
Deactivating the functions
4
The following must be checked when the function is being performed:
-
how far the cleaning cutter is inserted in the gas nozzle (lifting device moves
up/down)