5. Cleaning
Start from position B
approx. 50 mm / 1.97 in. above gas
nozzle clamping device
Speed: high speed mode
B
50 mm
1.97 in.
Move into the gas nozzle clamping
device
For details see page 36.
Speed: 10 cm/s (236.22 ipm)
Position the welding torch in the
clamping device:
The gas nozzle must sit on the in-
side of the holder.
Set
External signal "Clamp gas nozzle,
cleaning motor on"
Wait 0.5 sec.
"Gas nozzle clamped" query:
Low or High
"Gas nozzle clamped" query = High
"Gas nozzle clamped" query = Low
Stop
Error message:
Gas nozzle not clamped
Set
External signal "Swivel to the right"
Wait 0.5 sec.
"Swivel mechanism right" query:
Low or High