Care, maintenance and disposal
General The cleaning device generally needs no maintenance. However, to keep the clean-
ing device in good working condition for years to come, several points on care
and maintenance must be observed.
Before each
start-up
-
Check fill level in parting agent container and top up if necessary
-
Check fill level in parting agent spatter tray and empty if necessary
-
Check cleaning cutter for wear and replace if necessary
-
Empty the cleaning device spatter tray
-
If fitted, empty the wire cutter tray
-
Carry out a general visual inspection of the cleaning device and make sure
that any damage is repaired immediately (before start-up)
Daily
CAUTION!
Danger from cleaning agents containing solvents.
This can result in damage to property.
▶
Only use solvent-free cleaning products on the cleaning device.
1
Remove parting agent deposits and dirt from device
Weekly
CAUTION!
Danger from cleaning agents containing solvents.
This can result in damage to property.
▶
Only use solvent-free cleaning products on the parting agent container.
1
Check the parting agent container for soiling and clean if necessary
2
Blow through suction filter in parting agent container using compressed air
from the inside outwards through the suction hose (for more detailed inform-
ation see section Starting up the parting agent nebuliser from page 44)
Every 6 months
1
Open the device and check the pneumatic valves for
-
Leaks
-
The secure seating of all screws
-
The secure seating of all screw joints on the pneumatic valves
As necessary Open the device and
1
Clean inside of device using dry reduced compressed air
2
Lightly oil the lifting device cylinder guides
3
Restore the original condition of the device
71
EN