The parting agent does not spray
Parting agent container is full
Not enough spray
Adjust spray time
Parting agent hose suction filter in the parting agent container is
soiled
Clean the suction filter of the parting agent hose with compressed air
(for more detailed information, see section Starting up the parting
agent nebuliser from page 44)
No signal from robot
Check robot program
Parting-agent injection nozzle blocked
Clean parting-agent injection nozzle
Contact After-Sales Service (arrange for parting-agent injection
nozzle to be replaced)
Vacuum pump faulty
Contact After-Sales Service (arrange for vacuum pump to be re-
placed)
Mechanical fault on solenoid valve
Contact After-Sales Service (arrange for solenoid valve to be re-
placed)
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Welding torch is poorly cleaned or damaged
Lifting device not adjusted properly
Adjust the lifting device
Cleaning cutter not suited to welding torch shape
Fit the correct cleaning cutter
Cleaning cutter is worn
Replace cleaning cutter
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy: