Temporary error
Abnormal behav-
ior
When does the error
occur?
Inverter error unlikely
(check grid, solar modules)
See Fronius service code for details
List
Inverter error unlikely
(PC board / inverter must be repaired)
See Fronius service for details
code list
Are other devices also
showing the error?
YES NO
- Check grid
- Check TOTAL (IN) menu
- Check Error Counter (IN)
- Check grid parameters (IN)
Contact Fronius TechSupport
Contact Fronius TechSupport
Activate event logging
Connection type and telephone number
or IP address
Fronius DATCOM
installed?
YES NO
- When does the error occur and since when has it been occurring?
- How many devices are affected?
- Details about solar modules (strings, module grounding,
type of installation)
- Details of cabling (DC and AC)
- Hardware and software version

Table of Contents

Other manuals for Fronius Symo 5.0-3-M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Symo 5.0-3-M and is the answer not in the manual?

Fronius Symo 5.0-3-M Specifications

General IconGeneral
AC Nominal Output5.0 kW
Max. Input Voltage1000 V
MPPT Voltage Range200 - 800 V
Number of MPP Trackers2
Dimensions (H x W x D)645 x 431 x 204 mm
Weight19.9 kg
Protection RatingIP 65
Operating Temperature Range-25°C to +60°C
Max. Apparent AC Power5.0 kVA
AC Nominal Voltage3~ 230/400 V
AC Voltage Range184 - 264.5 V
Frequency50 / 60 Hz
THD< 3%
Protection ClassI
Maximum AC Power5000 VA
AC Nominal Frequency50/60 Hz
DC Input Voltage Range200 - 1000 V
Number of DC Connections2
Max. DC Short-circuit Current18.0 A
CoolingActive cooling