Ground conductor current
- The effective inner resistance of the ground conductor current measuring device may
be a maximum of 5 . (With higher resistances, measures must be taken to prevent
the occurrence of hazardous contact voltages.)
- The measuring range must comprise at least the values from 0.25 mA to 19 mA.
- The inspection facility must assess the measured current to be an effective value re-
gardless of the waveform.
Contact Current
- The effective inner resistance of the contact current measurement instrument must be
1 k to 2 k.
- If the current test circuit is accidentally connected to a voltage up to 120% of the nom-
inal grid voltage, the user must not be endangered and the test circuit must not be
damaged.
- The inspection facility must assess the measured current to be an effective value re-
gardless of the waveform.

Table of Contents

Other manuals for Fronius SYMO Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius SYMO Series and is the answer not in the manual?

Fronius SYMO Series Specifications

General IconGeneral
MPPT Number2
Frequency Range50 / 60 Hz
Operating Temperature Range-25°C to +60°C
CommunicationWiFi, Ethernet, RS485
AC Nominal Voltage3 x 230 V / 400 V
Output Voltage3 x 230 V / 400 V
Warranty5 years

Related product manuals