Technical data
General If the power source is designed for a special voltage, the technical data on the
rating plate applies. The mains plug, mains lead and their fuse protection must
be rated accordingly.
TP 4000 CEL
Mains voltage 3 x 400 V
Mains voltage tolerance +/- 15%
Mains fuse protection 35 A slow-blow
Mains connection
1)
Restrictions possible
Primary continuous
power
100% D.C.
2)
12.9 kVA
Cos phi 0.99
Welding current range MMA
TIG
10 - 380 A
10 - 380 A
Welding current at 10 min / 40°C
10 min / 40°C
10 min / 40 °C
40% D.C.
2)
60% D.C.
2)
100% D.C.
2)
380 A
360 A
320 A
Standardised working voltage MMA
TIG
20.4 - 35.2 V
14.5 - 33 V
Maximum working voltage MMA 53 V (380A)
80 V (10 A)
Open circuit voltage (pulsed) Peak value
Average value
95 V
60 V
Degree of protection IP 23
Mark of conformity S, CE
Type of cooling AF
Insulation class F
Dimensions l x w x h 625 x 290 x 475 mm
24.6 x 11.4 x 18.7 in.
Weight 36.1 kg
79.6 lbs
Power source efficiency at 380 A / 35.2 V 89 %
1) Connected to public grids with 230 / 400 V and 50 Hz
2) D.C. = Duty cycle
TP 4000 CEL MV
Mains voltage 10 - 380 A
10 - 380 A
Mains voltage tolerance +/- 10%
Mains fuse protection 200 - 240 V: 35 A
380 - 460 V: 35 A
108