Loading...
to7 | xxx
Note: xxx stands for a temperature value
Overtemperature in the power source
Allow power source to cool down, check air filter and clean if neces-
sary, check that fan is on
Cause:
Remedy:
tu0 | xxx
Note: xxx stands for a temperature value
Undertemperature in the power source primary circuit
Place power source in a heated room and allow it to warm up
Cause:
Remedy:
tu1 | xxx
Note: xxx stands for a temperature value
Undertemperature on the booster located in the power source
Place power source in a heated room and allow it to warm up
Cause:
Remedy:
tu2 | xxx
Note: xxx stands for a temperature value
Undertemperature in the power source secondary circuit
Place power source in a heated room and allow it to warm up
Cause:
Remedy:
tu3 | xxx
Note: xxx stands for a temperature value
Undertemperature in the wirefeeder motor
Place wirefeeder in a heated room and allow to warm up
Cause:
Remedy:
tu4 | xxx
Note: xxx stands for a temperature value
Undertemperature in the welding torch
Place welding torch in a heated room and allow to warm up
Cause:
Remedy:
tu5 | xxx
Note: xxx stands for a temperature value
Undertemperature in the cooling unit
Place cooling unit in a heated room and allow to warm up
Cause:
Remedy:
tu6 | xxx
Note: xxx stands for a temperature value
Undertemperature on the power source transformer
Place power source in a heated room and allow it to warm up
Cause:
Remedy:
tu7 | xxx
Note: xxx stands for a temperature value
Undertemperature in power source
Place power source in a heated room and allow it to warm up
Cause:
Remedy: