EasyManua.ls Logo

Fronius TransSteel 4000 Pulse - Transsteel 5000 Pulse MV Nc

Fronius TransSteel 4000 Pulse
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TransSteel 5000
Pulse MV nc
Mains voltage (U
1
) 3 x 200 V / 230 V / 400 V / 460 V
Max. effective primary current (I
1eff
)
3 x 200 V 39.5 A
3 x 230 V 36.3 A
3 x 400 V 20.6 A
3 x 460 V 18.1 A
Max. primary current (I
1max
)
3 x 200 V 66.7 A
3 x 230 V 57.4 A
3 x 400 V 32.5 A
3 x 460 V 28.6 A
Mains fuse
3 x 200 V / 230 V 63 A slow-blow
3 x 400 V / 460 V 35 A slow-blow
Mains voltage tolerance -10 / +15%
Mains frequency 50/60 Hz
Cos phi (1) 0.99
Max. permitted grid impedance Z
max
on PCC
1)
52.2 mOhm
Recommended residual-current cir-
cuit breaker
Type B
Welding current range (I
2
)
MIG/MAG 10 - 500 A
MMA 10 - 500 A
Welding current at 10 min / 40 °C
(104 °F)
U
1
: 200 V 35% / 500 A
60% / 420 A
100% / 360 A
U
1
: 208 - 460 V 40% / 500 A
60% / 420 A
100% / 360 A
Output voltage range according to
standard characteristic (U
2
)
MIG/MAG 14.3 - 39 V
MMA 20.2 - 40 V
Open circuit voltage
(U
0
peak / U
0
r.m.s)
57 V
Apparent power
at 200 V AC / 500 A / 40% ED
2)
23.08 kVA
at 400 V AC / 500 A / 40% ED
2)
22.49 kVA
132

Table of Contents

Related product manuals