EasyManua.ls Logo

Fronius TransSteel 4000 Pulse - Special 2-Step Mode; Special 4-Step Mode

Fronius TransSteel 4000 Pulse
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Special 2-step
mode
GPr
GPo
I
I-S
SLt-S t-ESL
I-E
+
t
I
"Special 2-step mode" is ideal for welding in higher power ranges. In special 2-
step mode, the arc starts at a lower power, which makes it easier to stabilize.
To activate special 2-step mode:
1
Select 2-step mode
2
In the Setup menu, set the t-S (starting current duration) and t-E (final cur-
rent duration) parameters to a value > 0
Special 2-step mode is activated.
3
In the Setup menu, set the SL (Slope), I-S (starting current), and I-E (final
current) parameters
Special 4-step
mode
+ +
I
I-S I-E
GPr SL SL
GPo
Special 4-step mode allows the starting and final current to be configured in ad-
dition to the advantages of 4-step mode.
64

Table of Contents

Related product manuals