71
EN-US
In the event of an error:
- Inspect torch hosepack, welding torch, and grounding cable for damage
- Check connections and contacts
- Check the cleanliness of the workpiece surface
Slope Time 1 (only available in 4-step mode)
Ramping time from the main current I
1
to the lowering current I
2
off / 0.01 - 9.9 s
Factory setting: 0.5 s
Slope Time 2 (only available in 4-step mode)
Ramping time from the lowering current I
2
back up to the main current I
1
off / 0.01 - 9.9 s
Factory setting: 0.5 s
Trigger
Torch trigger operating mode
off / on
Factory setting: on
off
Operating welding torch without torch trigger
High frequency ignition is deactivated.
on
TIG 2-step or 4-step mode
HF ignition
off / on
Factory setting: on
off
No HF ignition at the start of welding - welding started by contact ignition
on
HF ignition is activated
The HF ignition special indicator illuminates on the control panel when the "HF
ignition" parameter is set to "on".

Table of Contents

Other manuals for Fronius TransTig 210

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransTig 210 and is the answer not in the manual?

Fronius TransTig 210 Specifications

General IconGeneral
BrandFronius
ModelTransTig 210
CategoryWelding System
LanguageEnglish

Related product manuals