18
Safety measures
in normal opera-
tion
Before transporting the device, allow coolant to drain completely and detach
the following components:
- Wire-feed unit
- Wirespool
- Shielding gas cylinder
After transporting the device, the device must be visually inspected for dam-
age before commissioning. Any damage must be repaired by trained service
technicians before commissioning the device.
Only operate the device if all safety devices are fully functional. If the safety
devices are not fully functional, there is a risk of
- injury or death to the operator or a third party,
- damage to the device and other material assets belonging to the operator,
- inefficient operation of the device.
Any safety devices that are not functioning properly must be repaired before
switching on the device.
Never bypass or disable safety devices.
Before switching on the device, ensure that no one is likely to be endangered.
Check the device at least once a week for obvious damage and proper func-
tioning of safety devices.
Always fasten the shielding gas cylinder securely and remove it beforehand if
the device is to be transported by crane.
Only the manufacturer's original coolant is suitable for use with our devices
due to its properties (electrical conductibility, anti-freeze agent, material com-
patibility, flammability, etc.).
Only use suitable original coolant from the manufacturer.
Do not mix the manufacturer's original coolant with other coolants.
The manufacturer accepts no liability for damage resulting from use of a dif-
ferent coolant. In addition, all warranty claims will be forfeited.
The coolant can ignite under certain conditions. Transport the coolant only in
its original, sealed containers and keep well away from any sources of ignition.
Used coolant must be disposed of properly in accordance with the relevant na-
tional and international regulations. The coolant safety data sheet may be ob-
tained from your service centre or downloaded from the manufacturer's
website.
Check the coolant level before starting to weld and while the system is still
cool.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransTig 5000 and is the answer not in the manual?

Fronius TransTig 5000 Specifications

General IconGeneral
BrandFronius
ModelTransTig 5000
CategoryWelding System
LanguageEnglish

Related product manuals